ZinsLab.org

Steven D. Zins' Physics Projects

User Tools

Site Tools


a:datastructure

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
a:datastructure [2022/02/26 15:58]
sz
a:datastructure [2022/03/09 22:49] (current)
sz
Line 1: Line 1:
 ====== Data Structure and Volume ====== ====== Data Structure and Volume ======
  
-FOMMX follows the principles and terminology of Miller(1933) as much as possible. +The Fiber-Optic Michelson-Morley Experiment, FOMMX, data collection follows the principles and terminology of Miller (1933).
-In particular, the words sheet, column, and row follow Miller's usage.+
  
-Miller used a data collection spreadsheet preprinted with rows and columns(p213). +Miller used a data-collection spreadsheet preprinted with rows and columns (p213). 
-When a sound signal occurred, Miller estimated the fringe shift and called it out.+When a signal occurred, Miller estimated the interferometric fringe shift and called it out.
 An assistant recorded that number on the spreadsheet. An assistant recorded that number on the spreadsheet.
  
 As the interferometer turned through one revolution, the numbers were entered in one row. As the interferometer turned through one revolution, the numbers were entered in one row.
-The sound signal occurred sixteen times per revolution, and the data for each was recorded in the corresponding column. +The sound signal occurred sixteen times per revolution, and the data for each occurrence was recorded in the corresponding column. 
  
-The following list describes the data structure and timing used in FOMMX, with the corresponding value for Miller. +The following list describes the data structure and timing used in FOMMX.
-Numbers in [square brackets] or {curly braces} or <> are for planning new system.+
  
-  * Data Hierarchy 
     * Data Collection File: 1 Day.     * Data Collection File: 1 Day.
-    * Sheet: 30 minutes, 48 per Day (Miller's sample data collection sheet.) +    * Sheet: 30 minutes, 48 per Day  
-    * Row, Turn: 1 minute, 360˚. (A turn is one full cycle of rotation of interferometer arms.) +      * (A sheet is analogous to Miller's sample data collection sheet.) 
-    * Column: 2 seconds, 12˚. +    * Row, Turn: 1 minute, 360˚ per TurnThere are 30 Rows and Turns per Column and Sheet. 
-    * Reading: 0.23 seconds, 4.35 per second.  (Program reads a set of values from electronics and stores them.)+      * (A Turn is one full cycle of rotation of interferometer arms.) 
 +      * (A Row is a horizontal set of cells.) 
 +    * Column: 2 seconds, 12˚ per column. There are 30 Columns per Row and Turn and Sheet. 
 +    * Cell: A single number. There are 30 cells per row and 30 cells per Column
 +    * Reading: 0.23 seconds, 4.35 per second. Miller had one reading per cell. 
 +      * (Program reads a set of values from electronics and stores them.)
       * Readings per hour 15,660.       * Readings per hour 15,660.
       * Readings for 12,000 hours in 2020, 2021: 187,920,000.       * Readings for 12,000 hours in 2020, 2021: 187,920,000.
-  *  +  
-  * 2 sheets/points per hour (point on 4-epoch **plot**) 4 too many +
-    * 30 minutes/turns/rows per sheet +
-    * 48 Sheets/points per day, continuous, automated. (Miller: 2 sets/hour * 8 hour/day = 16 sets/day) +
-  * . +
-  * 30 columns per sheet row/turn/minute (18 too small for **fit**, esp for Half) greater importance +
-    * 2 seconds per column +
-    * 4,35 Readings per second +
-    * 8.7 Readings per column. (Miller: 1) +
-  *  +
-.+
  
-. 
- 
-The following is my initial configuration. This was changed on 2/15/22. 
-  * --96   Sheets per day(=24*4). (Miller 1-10 estimated) 
-  *  
-  * 18   Columns per turn. (Miller 16) 
-  * 20   Degrees per column. (Miller 22.5) 
-  *  
-  * 60   Seconds per turn. (Miller 45 estimated) 
-  * 3.33 Seconds per column. (=60/18).  
-  * 4,35 Readings per second. 
-  * 14.5 Readings per column. (Muller 1) 
-  *  
-  * 15  Rows (Interferometer turns) per sheet. (Miller 20) 
-  * 900 Seconds = 15 Minutes, per sheet. (Miller 900s estimated) 
-  *  
-  *  
-  * --96 Sheets per day, continuous, automated. (Miller's manual collection admitted far less) 
-  *  
-  * 270 = 18 * 15 Cells per sheet. (Miller 320) 
-  *  
-  * 25,920 = 96 * 270 Cells per day 
-  * 375,950 Readings per day 
-  * 14.5 = 375,950 / 25,920 Readings per Cell, approximately. (Miller 1) 
-  *  
-  * 12,000 hours total collected. 
-  * 500 days (equivalent) total collected 
-  * 187,975,000 = 500 * 375,950 readings total performed. 
a/datastructure.1645909091.txt.gz · Last modified: 2022/02/26 15:58 by sz